EasyManua.ls Logo

Fronius Ignis 150 - Ignis 180 & 180 MV Specifications

Fronius Ignis 150
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cos phi 0.99
Max. permitted mains impedance Z
max
at PCC
1)
32 mOhm
Recommended residual current circuit breaker Type B
Welding current range (I
2
) rod electrode 10-150 A
Welding current range (I
2
) TIG 10-150 A
Welding current for MMA welding 10 min / 40 °C
(104 °F)
35 %
150 A
60 %
110 A
100 %
90 A
Welding current for TIG welding 10 min / 40°C
(104°F)
35 %
150 A
60 %
110 A
100 %
90 A
Output voltage range according to standard char-
acteristic (U
2
) rod electrode
20.4-26.0 V
Output voltage range according to standard char-
acteristic (U
2
) TIG
10.4-16.0 V
Open circuit voltage (U
0
peak) 96 V
Protection class IP 23
Type of cooling AF
Overvoltage category III
Pollution degree according to IEC60664 3
EMC emission class A
Safety symbols S, CE
Dimensions (length x width x height) 365 x 130 x 285 mm
14.4 x 5.1 x 11.2 in.
Weight 6.3 kg
13.9 lb.
Idle state power consumption
at 230 V
15 W
Energy efficiency of the welding system at
150 A / 26 V
87%
1) Interface to a 230/400 V and 50 Hz public grid
Ignis 180
Mains voltage (U
1
) 1 x 230 V
Max. effective primary current (I
1eff
) 16 A
Max. primary current (I
1max
) 25 A
Max. apparent power (S
1max
) 5.75 kVA
Mains fuse 16 A slow-blow
50

Table of Contents

Related product manuals