Fronius Ignis 150 - Common Operational Faults

Fronius Ignis 150
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E37
Mains voltage too high
Pull out the mains plug immediately; ensure that the welding system
is being operated on the correct mains voltage
Cause:
Remedy:
E36, E41, E45
Mains voltage outside tolerance or maximum load of grid is too low
Ensure that the welding system is being operated on the correct
mains voltage; ensure that the correct fuse is set;
Cause:
Remedy:
E65 - E75
Communication error with the display
Switch device off and on again / contact after-sales service if a re-
peated occurrence
Cause:
Remedy:
No function
The device cannot be switched on
Mains switch is faulty
Contact After-Sales Service
Cause:
Remedy:
No welding current
Welding system is switched on, indicator for the selected welding process is lit
Welding power-lead connections have been disconnected
Establish proper welding power-lead connections
Poor or no earth
Establish a connection to the workpiece
There is a break in the power cable in the welding torch or electrode
holder
Replace welding torch or electrode holder
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
45
EN