Setup menu - Level 2
Welding para-
meters in the
level 2 Setup
menu
Paramet-
er Description Range Unit
Software version
The full version number of the currently
installed software is spread across a
number of displays and can be retrieved
by turning the adjusting dial.
Automatic switch-off (time Shut down)
If the device is not used or operated for a
specified period of time, it automatically
switches itself into Standby mode
Pressing any button on the control panel
will cancel Standby mode and the device
will be ready to resume welding
Factory setting: OFF
5 - 60
OFF
Minutes
Fuse
For displaying/setting the fuse used
Factory setting:
-
for mains voltage 230 V = 16 A
-
for mains voltage 120 V = 20 A
If a fuse is set on the welding system, the
welding system limits the power drawn
from the mains. This prevents the auto-
matic circuit breaker from tripping imme-
diately
At
230 V:
10 / 13 /
16 / OFF
(TP 180
MV only)
At
120 V:
15 / 16 /
20 / OFF
(TP 180
MV only)
Ampere
Ignis 150 - Ratio between set fuse and welding current:
Mains voltage Set
fuse
Welding cur-
rent elec-
trode
TIG
welding cur-
rent
Duty cycle
230 V 10 A 110 A 150 A 35%
13 A 130 A 150 A 35%
16 A 150 A 150 A 35%
Ignis 180 - Ratio between set fuse and welding current:
Mains voltage Set fuse Welding cur-
rent elec-
trode
TIG
welding cur-
rent
Duty cycle
230 V 10 A 125 A 180 A 40%
13 A 150 A 200 A 40%
16 A 180 A 220 A 40%
39