Specifying the charging range
It is possible to define a charging range with a min. and max. charging limit. In
this case, it is not possible for the battery to discharge.
Min. charging power
Max. charging power
500 W
3800 W
03:00 – 04:00
03:00 – 04:00
1.
Mo Tu We Th Fr Sa Su
Mo Tu We Th Fr Sa Su
2.
Limit
charging power
Max. charging
power 3800 W
Min. charging
power 500 W
Limit
discharge power
0 W
Specifying the discharging range
It is possible to define a discharging range with a min. and max. discharging limit.
In this case, it is not possible for the battery to charge.
Max. discharging power
Min. discharging power
3000 W
1000 W
13:00 – 14:00
00:00 – 23:59
1.
Mo Tu We Th Fr Sa Su
Mo Tu We Th Fr Sa Su
2.
Limit
charging power
Limit
discharge power
Max. discharge
power 3000 W
Min. discharge
power 1000 W
0 W
Specifying a defined charging power
A defined charging power can be specified by setting the min. and max. charging
power to the same value.
Min. charging power
Max. charging power
3000 W
3000 W
03:00 – 04:00
03:00 – 04:00
1.
Mo Tu We Th Fr Sa Su
Mo Tu We Th Fr Sa Su2.
Limit
charging power
Min./Max. charging
power 3000 W
Limit
discharge power
0 W
117