EasyManua.ls Logo

Fronius Primo GEN24 Series - Permissible Cables for the Data Communication Connection

Fronius Primo GEN24 Series
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ground electrode terminal (6-pin)
Select a sufficiently large cable cross section based on the actual device output.
2
2.5 – 16 mm
2
AWG 14–6
2.5 – 16 mm
2
AWG 14–6
2.5 – 16 mm
2
AWG 14–6
2.5 – 16 mm
2
AWG 14–6
2.5 – 16 mm
2
AWG 14–6
4
2.5 – 10 mm
2
AWG 14–8
2.5 – 10 mm
2
AWG 14–8
2.5 – 10 mm
2
AWG 14–8
2.5 – 10 mm
2
AWG 14–8
2.5 – 10 mm
2
AWG 14–8
* According to product standard IEC 62109, the ground conductor must
correspond to the phase cross-section for phase cross-sections ≤16 mm²,
while for phase cross-sections >16 mm², it must be at least 16 mm².
For a conductor cross-section of 1.5 mm
2
, the maximum permissible
cable length is 100 m.
** The cable cross-section must be dimensioned in accordance with the in-
stallation situation and the specifications of the battery manufacturer.
Permissible
cables for the
data communic-
ation connection
Cables with the following design can be connected to the terminals of the invert-
er:
-
Copper: round, solid
-
Copper: round, fine-stranded
IMPORTANT!
Connect the individual conductors to an appropriate ferrule if several individual
conductors are connected to one input of the push-in terminals.
WSD connections with push-in terminal
Dis-
tance
max.
Strip-
ping
length
Cable re-
commenda-
tion
100 m
109 yd
10 mm
0.39 inch
0.14-1.5 mm
2
AWG 26 - 16
0.14-1.5 mm
2
AWG 26 - 16
0.14-1 mm
2
AWG 26 - 18
0.14-1.5 mm
2
AWG 26 - 16
min. CAT 5
UTP (un-
shielded
twisted pair)
Modbus connections with push-in terminal
Dis-
tance
max.
Strip-
ping
length
Cable re-
commenda-
tion
300 m
328 yd
10 mm
0.39 inch
0.14-1.5 mm
2
AWG 26 - 16
0.14-1.5 mm
2
AWG 26 - 16
0.14-1 mm
2
AWG 26 - 18
0.14-1.5 mm
2
AWG 26 - 16
min. CAT 5
STP (shiel-
ded twisted
pair)
IO connections with push-in terminal
Dis-
tance
max.
Strip-
ping
length
Cable re-
commenda-
tion
30 m
32 yd
10 mm
0.39 inch
0.14-1.5 mm
2
AWG 26 - 16
0.14-1.5 mm
2
AWG 26 - 16
0.14-1 mm
2
AWG 26 - 18
0.14-1.5 mm
2
AWG 26 - 16
Single con-
ductor pos-
sible
68

Table of Contents

Other manuals for Fronius Primo GEN24 Series

Related product manuals