Operating state Description
Min. state of charge (SOC)
achieved
Battery has reached the minimum SOC set or
specified by the manufacturer. The battery cannot
be discharged any further.
Energy saving mode
(standby)
The system has been put into energy saving mode.
Energy saving mode is automatically ended as
soon as sufficient excess energy is available again.
Start The storage system starts from energy saving
mode (standby).
Forced re-charging The inverter re-charges the battery, in order to
maintain the set minimum SOC (state of charge)
or the SOC specified by the manufacturer (pro-
tection against deep discharge).
Deactivated The battery is not active. It has either been deac-
tivated/switched off, or an error means that no
communication with the battery is possible.
23

Table of Contents

Other manuals for Fronius Primo GEN24 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo GEN24 Series and is the answer not in the manual?

Fronius Primo GEN24 Series Specifications

General IconGeneral
TypeHybrid Inverter
THD< 3 %
Number of MPP trackers2
Max. efficiency98.1 %
Protection classIP66
DC isolationYes
AC Output Power3.0 kW to 10.0 kW
Max. apparent AC power3.0 kVA to 10.0 kVA
Max. output current (at grid voltage)13.0 A to 43.5 A
AC nominal voltage230 V
Number of DC connections2
Operating Temperature Range-25°C to +60°C