37
EN
TP 5000 CEL MV
Mains voltage 3x200-240 V
3x380-460 V
Mains voltage tolerance +/- 10 %
Mains fuse protection (slow-blow) 200-240 V: 63 A
380-460 V: 35 A
Mains connection
1)
Restrictions possible
Primary continuous power (100% d.c.
2)
) 16.3 kVA
Cos Phi 0,99
Efficiency 90 %
Welding current range Rod electrode 10 - 480 A
TIG 10 - 480 A
Welding current at 10 min / 40°C 40 % d.c.
2)
480 A
10 min / 40°C 60 % d.c.
2)
415 A
10 min / 40°C 100 % d.c.
2)
360 A
Standard working voltage Rod electrode 20.4 - 39.2 V
TIG 14.5 - 38 V
Max. working voltage Rod electrode 48 V (480 A)
80 V (10 A)
Open-circuit voltage pulsed peak value 95 V
mean value 60 V
Degree of protection IP 23
Type of cooling AF
Insulation class F
Dimensions L x W x H mm 625/290/475
Weight 40.5 kg
1) To 230/400 V, 50 Hz public supply mains
2) d.c. = duty dycle
Insulation class F
Dimensions L x W x H mm 625/290/475
Weight 37 kg
1) To 230/400 V, 50 Hz public supply mains
2) d.c. = duty dycle
TP 5000 CEL
(continued)