EasyManua.ls Logo

Fronius TransPocket 5000 CEL - Hot-Start Function; ELN Function (Electrode-Line Selection)

Fronius TransPocket 5000 CEL
163 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
EN
In order to achieve an optimum welding result, it is necessary in some cases to set the
Hot-Start function. The information required to set the Hot-Start function is found in the
”Hot-Start Function” chapter below.
Benefits:
- Improved ignition properties, even for electrodes with inherently bad ignition pro-
perties
- Better smelting of the base material during the starting phase, therefore fewer cold
points.
- Largely avoids slag inclusions.
NOTE! Please refer to the chapter ”Set-up menu: Level 1” for an explanation of
the settings of the available parameters.
Hot-Start func-
tion
Fig. 25 Example for the ”Hot-Start” function
Legend:
I
H
Primary current = set welding
current
HCU Hot-start current ... 0 - 100 %,
factory setting: 50 %
Hti Hot-current time ... 0 - 2,0 s,
factory setting: 0,5 s
Function
During the selected hot-current time (Hti), the welding current is increased to a certain
value. This value exceeds the selected welding current (I
H
) by 0 to 100% (HCU).
Example: The welding current setting (I
H
) is 200A. The hot-start current setting is 50%.
During the hot-start time (Hti, e.g. 0.5s), the actual welding current is 200A + (50% of
200A) = 300A.
ELN function
(electrode-line
selection)
The Eln function can be parametrised separately for each of the proces-ses “Rod
electrode welding”, “Rod electrode welding with CEL electrode” and “Special proces-
ses”.
NOTE! For information on how to set the available parameters, please see the
section headed “Set-up menu: Level 1”.
“con” parameter (constant welding current)
If the “con” parameter has been set, the welding current is kept constant, regardless of
the welding voltage. The result is a vertical characteristic (4) (Fig.25).
The “con” parameter is especially suitable for rutile and basic electrodes, as well as
gouging. This is why the “con” parameter is also the factory setting if the process “Rod
electrode welding” is selected.
I (A)
t
200A
0,5 s
1 s
1,5 s
300A
I
H
HCU
Hti
For gouging, set dynamics to ”100”.
Parameter “0.1 - 20” (falling characteristic with adjustable slope)
Parameter “0.1-20 ” is used for setting a falling characteristic (5) (Fig.25). The setting
range extends from 0.1 A / V (very steep) to 20 A / V (very shallow).
Setting a shallow characteristic (5) is only advisable for cellulose electrodes.

Table of Contents

Other manuals for Fronius TransPocket 5000 CEL

Related product manuals