9
EN
Fig.8 TR 4000 remote-control unit
(33) Parameter switchover button ... for
selecting and displaying the parame-
ters “Welding voltage” and “Welding
current” on the digital display
NOTE! When you change a
parameter, the value for this
parameter is brie-fly indicated -
for control purposes - on the
digital display of the r.c. unit.
(34) Welding-current setting dial ... for
selecting the welding current
TR 4000 remote-
control unit
(35) Hot start setting dial
Manual electrode welding ... influences the welding current during the ignition
phase
0 no influence
10 100% increase in welding current during the ignition phase
(34)
(33)
(36)
(35)
NOTE! Parameters that can be set on the remote-control unit cannot be
changed on the power source. Parameter changes can only be made on the
remote-control unit.
TR 3000 remote-
control unit
(continued )
(36) Arc-force setting dial
Manual electrode welding ... for influencing the short-circuiting amperage at the
instant of droplet transfer
0 soft, low-spatter arc
100 harder, more stable arc
NOTE! Parameters that can be set on the remote- control unit cannot be
changed on the power source. Parameter changes can only be made on the
remote-control unit.
Fig.9 TR 1000 remote-control unit
Fig.10 TR 1100 remote-control unit