EasyManua.ls Logo

Fronius VR 5000 - Page 103

Fronius VR 5000
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
103
EN
no | Prg
Cause: No preconfigured program has been selected
Remedy: Select a configured program
no | IGn
Cause: "Ignition time out" function is active; no current started flowing before the
length of wire specified in the set-up menu had been fed. The power source
safety cut-out has tripped.
Remedy: Shorten the wire end; press the torch trigger again; clean the surface of the
workpiece; if necessary, increase the wire length until the safety cut-out trips
in "Set-up menu: Level 2".
EPG | 17
Cause: The welding program selected is invalid
Remedy: Select valid welding program
EPG | 29
Cause: The required wire-feed unit is not available for the selected characteristic
Remedy: Connect correct wire-feed unit, check plug connections for the hosepack
EPG | 35
Cause: Measurement of the welding circuit resistance "r" failed
Remedy: Check grounding cable, current cable or hosepack and replace if necessary,
recalculate welding circuit resistance "r"
no | GAS
Cause: The Gas watchdog option has detected that there is no gas pressure
Remedy: Connect a new gas cylinder or open the gas cylinder valve/pressure regulator,
restart "Gas watchdog" option, reset "no | GAS" error message by pressing
any button.

Table of Contents

Other manuals for Fronius VR 5000

Related product manuals