68
MIG/MAG standard manual welding
General The MIG/MAG standard manual welding process is a MIG/MAG welding process with no
synergic function.
Changing one parameter does not result in any automatic adjustments to the other param-
eters. All of the variable parameters must therefore be adjusted individually, as dictated by
the welding process in question.
Available parame-
ters
The following parameters are available in MIG/MAG manual welding:
Wire feed speed
1 m/min (39.37 ipm) - maximum wire feed speed, e.g. 25 m/min (984.25 ipm)
Welding voltage
TSt 3500: 15.5 - 31.5 V
TSt 5000: 14.5 - 39 V
Dynamic
... for influencing the short-circuiting dynamic at the moment of particle transfer
Welding current
Only for displaying the actual value
MIG/MAG stand-
ard manual weld-
ing - manual
control panel
Press the Process button to select the desired welding process:
MIG/MAG welding
Press the Mode button to select the desired MIG/MAG mode:
2-step mode
4-step mode
IMPORTANT! Under certain circumstances, welding parameters that have been set on a
control panel of a system component (TR 2000 and TR 3000 remote control units or robot
interface) cannot be changed on the control panel of the wire-feed unit.
Use the wire feed speed adjuster to set the required value for the wire feed speed
Use the welding voltage adjuster to set the required value for the welding voltage
Open the gas cylinder valve
Set the shielding gas flow rate:
If there is a Feeder inching/Gas test button:
- Press the Feeder inching/Gas test button upwards
- Turn the adjusting screw on the underside of the pressure regulator until the pres-
sure gauge shows the required gas flow rate
- Press the Feeder inching/Gas test button upwards again
If there is no Feeder inching/Gas test button:
- Press the Mode button to select 4-step mode
- Set the "Ito" parameter to "Off" in the set-up menu
- Disengage the feed rollers
1
2
3
4
5
6