69
EN
CAUTION!
Risk of injury and damage from electric shock and from the wire electrode emerging
at speed from the torch.
When pressing the torch trigger:
► keep the welding torch away from your face and body
► wear suitable protective goggles
► do not point the welding torch at people
► make sure that the wire electrode does not touch any conductive or earthed parts, such
as the housing, etc.
- press the torch trigger briefly
- turn the adjusting screw on the underside of the pressure regulator until the pres-
sure gauge shows the required shielding gas flow rate
- press the torch trigger again briefly
- engage the feed rollers
CAUTION!
Risk of injury and damage from electric shock and from the wire electrode emerging
at speed from the torch.
When pressing the torch trigger:
► keep the welding torch away from your face and body
► wear suitable protective goggles
► do not point the welding torch at people
► make sure that the wire electrode does not touch any conductive or earthed parts, such
as the housing, etc.
Press the torch trigger and start welding
Adjustments
while welding -
manual control
panel
To obtain the best possible welding results, the arc-force dynamic parameter will some-
times need to be adjusted.
Set the required arc-force dynamic using the Dynamic buttons.
The value of the welding parameter is indicated by the LEDs located between the but-
tons.
MIG/MAG stand-
ard manual weld-
ing - Synergic A
control panel
Press the Process button to select the desired welding process:
MIG/MAG standard manual welding
Press the Mode button to select the desired MIG/MAG mode:
2-step mode
4-step mode
In MIG/MAG standard manual welding, special 4-step mode corresponds to conventional
4-step mode.
IMPORTANT! Under certain circumstances, welding parameters that have been set on a
control panel of a system component (TR 2000, TR 3000, robot interface) cannot be
changed on the control panel of the wire-feed unit.
Press the Parameter selection button to select the wirefeed speed parameter
Use the adjusting dial to set the desired value for the wire feed speed
7
1
1
2
3
4