71
EN
Adjustments
while welding -
Synergic A con-
trol panel
To obtain the best possible welding results, the arc-force dynamic parameter will some-
times need to be adjusted.
Press the "Parameter selection" button to select the arc-force dynamic parameter
Use the adjusting dial to set the desired arc-force dynamic value
The welding parameter value is shown in the digital display located above it.