29
EN
(5) "Dynamic" buttons
for influencing the short-circuiting dynamic at the moment of droplet transfer
- ... harder, more stable arc
+ ... soft, low-spatter arc
(6) HOLD indicator
Every time you finish a welding operation, the actual values for welding current and 
welding voltage are stored, and the HOLD indicator lights up.
Adjustment aid 
for Manual con-
trol panel
For selected material/shielding gas combinations, the wire-feed unit includes adjustment 
aids in the form of films that can be easily attached to and removed from the Manual control 
panel. The adjustment aids have additional scales that correspond to the sheet thickness 
used. If both the adjusters are set to the current value for the sheet thickness, this will pro-
duce a good basic setting for the respective material / shielding gas combination.
(1) Adjustment aid applies with the specified material / shielding gas combina-
tion
e.g.:
- Steel = Material
- Ø 1.0 mm = Wire diameter
- 100 % CO
2
 = Shielding gas
*) In conjunction with the VRD option, the currently selected welding process indica-
tor is simultaneously an additional indicator:
- The indicator is permanently lit: the Voltage Reduction Device (VRD) is active 
and is limiting the output power to less than 35 V.
- The indicator starts to flash as soon as a welding action starts in which the out-
put voltage can exceed 35 V.