CODE ERROR MESSAGE EXPLANATION
E01 REMOVE DISCARD (Right)
A product cook is started on the right side of a split vat
or in a full vat that has a different setpoint other than the
current vat temperature.
E02 REMOVE DISCARD (Left)
A product cook is started on the right side of a split vat
or in a full vat that has a different setpoint other than the
current vat temperature.
E03 ERROR TEMP PROBE FAILURE TEMP Probe reading out of range.
E04 HI 2 BAD High limit reading is out of range.
E05 HOT HI 1
High limit temperature is past more than 410°F (210°C),
or in CE countries, 395°F (202°C).
E06 HEATING FAILURE
A component has failed in the high limit circuit such as
computer, interface board, contactor or open-high limit.
E07 ERROR MIB SOFTWARE Internal MIB software error.
E08 ERROR ATO BOARD
MIB detects ATO board connection lost; ATO board
failure.
E09 ERROR PUMP NOT FILLING
Oil not returning to vat quickly. Possible problems: dirty
pad, bad or missing O-rings, tripped or defective lter
pump, actuators or linkage.
E10 ERROR DRAIN VALVE NOT OPEN
Drain valve failed to open; the valve’s position is
unknown.
E11 ERROR DRAIN VALVE NOT CLOSED
Drain valve failed to close; the valve’s position is
unknown.
E12 ERROR RETURN VALVE NOT OPEN
Return valve failed to open; the valve’s position is
unknown.
E13 ERROR RETURN VALVE NOT CLOSED
Return valve failed to close; the valve’s position is
unknown.
E14 ERROR AIF BOARD MIB detects AIF missing; AIF board failure.
E15 ERROR MIB BOARD
Cooking computer detects MIB connections lost;
check software version on each computer. If versions
are missing, check CAN connections between each
computer; MIB board failure.
E16 ERROR AIF PROBE AIF RTD reading out of range.
E17 ERROR ATO PROBE ATO RTD reading out of range.
E18 Not Used
E19 M3000 CAN TX FULL Connection between computers lost.
E20 INVALID CODE LOCATION SD card removed during update.
E21
FILTER PAD PROCEDURE ERROR
(Change Filter Pad)
25 hour timer has expired or dirty lter logic has
activated.
E22 OIL IN PAN ERROR The MIB has detected oil may be in the pan.
E23 CLOGGED DRAIN (Gas) Vat did not empty during ltration.
E24
OIL RETURN (level) SENSOR FAILED
(Gas)
Oil return sensor may have failed.
E25 RECOVERY FAULT Recovery time exceeded maximum time limit.
E26 RECOVERY FAULT CALL SERVICE
Recovery time exceeded maximum time limit for two or
more cycles.
E27 LOW TEMP ALARM
Oil temperature has dropped lower than 15°F (8°C) in
idle mode or 45°F (25°C) in cook mode.