20. HUMAN SENSOR
(Table 16)
Mode Cooling/ Dry Heating
Target temperature Setting temp.+2°C Setting temp.- 4°C
21. OUTDOOR UNIT LOW NOISE OPERATION
The Outdoor unit low noise operation functions by pressing OUTDOOR UNIT LOW NOISE button
on the remote controller.
This operation stops the PFC control, and changes the Current release operation/ release value.
Outdoor unit low noise operation mode can be used during cooling,
heating and automatic operation. It can not be used in Fan and Dry mode
The Human sensor functions by pressing SENSOR button on the remote controller.
When the sensor detects that there is no one in the room for 20 minutes or more,
it automatically changes the operation as below settings.
When someone comes back into the room, the human sensor will detect this, and
automatically revert to the original settings.
Cool/ Dry
Current release
Operation/ Release value
4.5A / 4.0A
Heat
6.5A / 6.0A
(Table 17)
90°
7 m
7 m
50° 50°
Vertical angle 90°(Side view) Horizontal angle 100°(Top view)
( Application range )
The sensor unit should detect when the human body (estimate: 100cmX30cm) or the object
which has more than 4 degreesC temp, difference from the background and are crossed with
1.0m/s speed in front of the sensor unit.
01-14
22. POWERFUL OPERATION
The Powerful operation functions by pressing POWERFUL button on the remote controller.
The indoor unit & outdoor unit will operate at maximum power as shown in Table 18.
Release Condition is as follows.
[Cooling / Dry]
- Room tenperature < Setting temperature - 1.5°C or Operation time has passed 20 minutes.
COMPRESSOR FREQUENCY Maximum
FAN CONT. MODE Powerful
SETTING LOUVER Cooling/ Dry : 4, Heating : 7
(Table 18)
Powerful operation
=
=
[Heating]
- Room tenperature > Setting temperature +1.5°C or Operation time has passed 20 minutes.