Chapter 5 Setup
5.1 Basic Setup
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-
Copyright 2013 FUJITSU LIMITED P3AM-4832-07ENZ0
90
5.1.2 Powering On
Turn on the PC terminal and the ETERNUS DX Disk storage system.
Follow the procedure below to turn on the ETERNUS DX Disk storage system.
Procedure
1 Press the Power switch of the controller enclosure.
The POWER LEDs on the controller enclosure and the drive enclosures are turned on.
Before turning on the ETERNUS DX Disk storage system, make sure that the main line switches of the power
distribution units and the PSU switches on the power supply units of the ETERNUS DX Disk storage system are
"ON" and that the LINE LEDs of the drive enclosures are green.
• After turning the power on, it takes about two minutes for the ETERNUS DX Disk storage system to
become READY (i.e. the READY LED turns on). If an error is detected during the initial power-on diagnostic
phase, a longer time (up to ten minutes) may be required before the READY LED turns on.
• When turning on the ETERNUS DX Disk storage system for the first time, volume formatting operation,
which is set as factory default, may be performed. However, the ETERNUS DX Disk storage system setting
operation can be continued. When canceling a volume format, delete the volume. For details on how to
delete volume, refer to "ETERNUS Web GUI User's Guide".
Controller enclosure
Drive enclosure
Drive enclosure
Power switch

Table of Contents