Example 2:
Position: Middle
Selected range = Enable, Start = 0 mm, End = 300 mm
Multifeeds are detected only within the area of light blue.
Example 3: (Bad Example)
Position: Middle
Selected range = Enable, Start = 100 mm, End = 102 mm
Since the detection range (length) is less than 5 mm,
multifeeds cannot be detected accurately.
HINT
When you use detection by overlapping, accuracy of multifeed detection
may drop if the documents are glued firmly or attached together by static
electricity.