22 Service Supplement RX200 S4
Replacing the chassis ID / temperature sensor Replacement routines
© cognitas. Gesellschft für Technik-Dokumentation mbH 2008 Pfad: J:\RX200S4\Doku\Suppl\EN\rx200s4-ss-en.k04
Ê Fasten the front panel module with the screw in the housing.
Ê Plug the front panel cable on the connector CN1 on the system board.
Ê Reinsert the air duct. Make sure that the hooks of the air duct engage in the
fan cage.
Ê Close the server and plug in the power plugs (detailed description see the
Options Guide).
4.3 Replacing the chassis ID / temperature
sensor
In this server, the chassis ID/temperature sensor is located on the front panel
board. Therefore, to replace the chassis ID/temperature sensor, you must
replace the front panel module (see section “Replacing the front panel module”
on page 20).
I To enable ServerView and ServerStart to identify the system, the chassis
ID prom must be reprogrammed with the ChassisIDProm tool after the
new front panel module has been installed.
The tool can be downloaded from the Fujitsu Siemens Computers
Service and Support page (URL:
http://extranet.fujitsu-siemens.com/service/information/intelservers/tools).
4.4 Replacing the fan board
Ê Open the server as described in the section “Preparation” on page 17.
Ê Lift up the air duct and take it out as described in the section “Removing the
air duct” on page 19.
Ê Remove all cables from the fan board.
Ê Remove all system fans from the fan cage (description see the Operating
Manual).