RX200 S5 Operating Manual 59
Starting up and operation Controls and indicators
Hard disk drive indicators
Figure 13: Indicators on the 2.5-inch HDD module
1 HDD BUSY (green)
Lights up: HDD in active phase
Does not light: HDD inactive (drive inactive)
2 HDD FAULT (orange)
(in conjunction with a RAID controller)
Does not light: no HDD error
Lights up: HDD Faulty or Rebuild Stopped (drive defective, needs
replacing, a rebuild process was stopped or the HDD module is not
correctly inserted)
Slow flashing: HDD Rebuild (the data is being restored after changing
a drive)
Fast flashing: HDD Identify
Four fast blinks/pause: HDD Predicted Fault
Two fast flashes/pause: HDD Hot Spare (Hot spare drive active. The
corresponding drive has failed).