46 Service Supplement RX600 S6
Replacement routines
Ê Install the hot-plug PCI divider insert as follows:
Adjust the hot-plug PCI divider insert over the hole in the system board
(see arrow).
Push the safety pin (see figure 19 on page 39) into the hole until it snaps
into place.
Ê Install the following components:
UFM if present (see page 51)
SAS/SATA RAID controller card (see page 26)
I/O riser card (see page 26)
Expansion cards (see the Operating Manual and the Options Guide).
All memory boards and memory dividers (see the Operating Manual).
Ê Close the server as described in section "Closing the server" on page 22.
Ê Reconnect all external cables to the server.
I To ensure correct operation, make sure you do the following after
installing the new system board:
Update the BIOS and the iRMC S2 firmware
Set the current Date and Time in BIOS menu
Default- and customer-specific BIOS settings are automatically restored
to the new system board BIOS in the background during first POST.
If applicable, activate TPM functionality in the system BIOS under Security >
TPM (Security Chip) Setting > Security Chip. For more information, refer to the
"System Board D3141 BIOS Setup Utility for PRIMERGY RX600 S6" manual.
This completes the replacement of the system board.