Management Agent Telnet Interface
22 ServerView BX900 Management Blade
3.3.4.4 Server Blade Memory
This option provides information on the server blade memory. The information is displayed in two tables:
3.3.4.5 Server Blade Voltage Table
This option provides information on the server voltage. The following parameters are displayed:
CPU Status Displays the CPU status. The values displayed will be:
OK
NOT_PRESENT
ERROR
CRITICAL
MISSING_TERMINATION
CPU Name Displays the CPU name.
CPU Socket Designation Displays the CPU socket designation.
CPU Manufacturer Displays information on the CPU manufacturer.
CPU Clock Displays the CPU clock.
Table Description
Server Blade Memory Information
Tabl e
Displays information on the total size of the memory, as well as on the
error count, the error reset record and the error count start time.
Server Blade Memory Modules Table Displays the status of each memory module, together with memory type
and error information.
Parameter Description
Server Voltage Designation Displays the voltage designation for the server blade.
Server Voltage Status Displays the voltage status for the server blade. The values displayed will be:
NOT_AVAILABLE
OK
TOO_LOW
TOO_HIGH
Server Voltage Minimum Value Displays the minimum voltage value for the server blade.
Server Voltage Maximum Value Displays the maximum voltage value for the server blade.
Server Voltage Current Value Displays the current voltage value for the server blade.
Server Voltage Nominal Value Displays the nominal voltage value for the server blade.
Parameter Description