GAGGIA ANIMA 05 TROUBLESHOOTING
Pag. 8/9
IMPORTANT NOTE: to execute the Steam-Out procedure the
DREGDRAWER must be in place and the DOOR must be closed.
If these 2 conditions are not respected a warning message is shown
on the display and the Steam-Out is interrupted.
The machine starts the Steam Out and in the display appears the
indication “ON”.
While the Steam Out runs the Electro valve is opened and water
comes out the Water/Steam pipe.
When the Steam Out is complete the message “COMPLETE” is
shown on the Display.The Electro valves automatically closes and the
machine can be switched off.
When the Steam-Out is complete the following parameters are reset to their default values:
Length “Espresso” product (Default 145 impulses)
Length “Espresso Lungo” product (Default 345 impulses)
Length “Cappuccino” (Coffee + Milk product) (Default 170 impulses coffee & 34sec milk)
Length “Milk” product (Default 34 seconds)
Stand-By Time (Default 15 minutes)
Count Coffee (Default 0)
The request for Priming the Circuit at the fi rst switch on is set.
Brewing Unit Empty
Aroma Strength (Default 3 beans)
BU current array (BU during rinsing) (Default 150mA)
Grinder Sensing Array Default 2000ms)
Grinding time Aroma Very Light (1 Bean) (Default 3000ms)
Grinding time Aroma Light/Medium (2/3 Beans) (Default 3500ms)
Grinding time Aroma Strong/Extra Strong
(4/5 Beans)
(Default 4000ms)
Filter Presence (Default OFF)
Filter Pulses (Default 0)
Last Error Log (Default 0)
Coffee Duct Empty = TRUE (To grind more fi rst time after steam-out and refi ll duct with coffee)