DMC-40x0 Command Reference EC • 89
EC
FUNCTION: ECAM Counter
DESCRIPTION:
The EC function sets the index into the ECAM table. This command is only useful when entering
ECAM table values without index values and is most useful when sending commands in
binary. See the command, ET.
ARGUMENTS: EC n where
n is an integer between 0 and 256.
n = ? Returns the current value of the index into the ECAM table.
USAGE: DEFAULTS:
While Moving Yes Default Value 0
In a Program Yes Default Format 1.0
Command Line Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_EC contains the current value of the index into the ECAM table.
RELATED COMMANDS:
EA Choose ECAM master
EB Enable ECAM
EG Engage ECAM
EM Specify ECAM cycle
EP Specify ECAM table intervals & staring point
EQ Disengage ECAM
ET ECAM table
EXAMPLES:
EC0 Set ECAM index to 0
ET 200,400 Set first ECAM table entries to 200,400
ET 400,800 Set second ECAM table entries to 400,800