3E1151SmartScale800UserManual
61
ProcedureforweighingstaticTraitloads
1. TurnthemodeselectswitchtoF(Finemode).
2. FollowtheprocedureoutlinedinCreatinganewtraitweighingsession(p
55).
3. Ensurethatthedisplayedweightiszero.TozerotheScales,presstheblue
Zerobutton.
Note:The iconisnotdisplayedinFinemode.
4. Placetheloadontotheplatform.
5. Torecordtraitvalues,press
todisplaytheTraittable.
Note:TheTraitfieldsdisplayeddependonthetraittableselectedwhenyou
createdthesession.
6. Enterthevaluesintothe"Trait"fieldsadjacenttotherelevantlabels.
7. Pressthegreen
Weighbutton,torecordtheweight.
Thestatisticsscreenupdatesimmediately.Theweightscreendoesnot
updateuntiltheloadisremovedfromtheweighingplatform.
8. Removetheloadfromtheplatform.Theweightscreenupdates.
9. RepeattheprocedurefromStep3,forsubsequentitemstobeweighed.
Attheendoftheweighingsession
1. SwitchtheScaleoffbyturningthemodeselectswitchtothe position.
2. Disconnecttheloadbarcables.
3. Fittheprotectivecapstotheloadbarcables.
4. FittheprotectivecapstotheScale.

Table of Contents