46
WWW.GATEE.EU
USER GUIDE
5.3.2 Advanced functions
CYCLE DETECTION
30-ROUNDS LIMIT
GEAR RATIO
SNIPER DELAY
AUG MODE
In exceptional cases, you can turn the cycle detection off.
An AEG can continuously fire max. 30 BB’s. To fire more BB’s, you must release the trigger
before. This is a protection against trigger jam.
Important: In case of an emergency, you can also stop firing by switching the fire selector
position.
To make the PRE-COCKING working with the highest level of precision you should define
the gears type in your AEG. Available types: STOCK, TORQ, SPEED, DSG.
Lets you to set delay between each SEMI shots to simulate the delay from reload or recoil.
You can set 0.5s, 1s, 2s or 3s delay. You can also turn on the vibration, which will inform you
that you are able to fire the shot.
Activates two stage trigger. You can set the first trigger stage with TRIGGER SENSITIVITY
function, and the second one with AUG MODE function. Pulling the trigger slightly (first
stage) produces SEMI or BURST fire and pulling the trigger further (second stage)
produces BURST or AUTO fire (depending on the fire selector mode).