48
WWW.GATEE.EU
USER GUIDE
Alarm vibrations
EXPLANATION
Too high current.
The battery is discharged.
VIBRATIONS
1 short low frequency
2 short low frequency
3 short low frequency
UVP1
VIBRATIONS: 2x
Protection against Over-Discharge of the Battery (BATTERY PROTECTION) was activated.
POSSIBLE REASON: WHAT TO DO:
6.2 Trouble codes and warnings (DTC)
UVP2
Voltage dropped under 3.75V which is critical for TITAN to work properly.
POSSIBLE REASON: WHAT TO DO:
- low frequency vibration
The trigger sensor error or the motor was not
detected or the device temperature is too high
or the selector error.
1. Charge the battery.
2. Check if the battery type and number of cells are
setup correctly.
1. The battery is discharged.
2. The battery type or number of battery cells is set up
incorrectly.
1. Charge the battery.
2. Use a battery with more capacity or more voltage.
3. Do not use any adapters.
4. Use standard or high-torque motors instead of
high-speed.
5. Check and fix the motor wires insulation.
6. Unjam the motor.
7. Replace the motor.
1. The battery is discharged.
2. Inadequate battery type to AEG configuration.
3. Too much electrical resistance between TITAN and
the battery.
4. Motor too strong for the connected battery.
5. Motor connections short circuit.
6. Motor is jammed.
7. Motor is damaged.