ocp1
Overcurrent Protection is activated.
1. Unjam the motor.
2. Replace the motor.
3. Check and fix the motor wires insulation.
1. Motor is damaged.
2. Motor is jammed.
3. Motor connections short circuit.
POSSIBLE REASON: WHAT TO DO:
VIBRATIONS: 1X
Ocp2
TITAN detected current over 220A. Short-circuit protection activated.
1. Check and fix the motor wires insulation.
2. Unjam the motor.
3. Replace the motor.
1. Motor connections short circuit.
2. Motor is jammed.
3. Motor is damaged.
POSSIBLE REASON: WHAT TO DO:
OTP
TITAN temperature is too high. Over-Temperature Protection is activated.
1. Wait until temperature will have dropped.1. Outside temperature is too high in correlation with
the demanding AEG.
2. Frequent short circuits and TITAN electrical
overloads.
POSSIBLE REASON: WHAT TO DO:
MOTOR DISC
TITAN didn't detect the motor.
1. Connect the motor.
2. Replace the motor.
1. Motor is not connected.
2. Motor is damaged.
POSSIBLE REASON: WHAT TO DO: