1.6 Operating Environment
Please follow the guidelines when considering a suitable location to set the LaserPro E200. Improper work
environments may lead to operational malfunction and/or unsafe working conditions. The LaserPro E200
should be placed and operated in a standard office-type environment.
Avoid environments where the machine is exposed to high levels of dust, temperature
(temperatures exceeding 30°C or 85°F) or humidity (humidity exceeding 70% or where the
ambient temperature is near the dew point).
Avoid small, enclosed areas with poor ventilation.
Avoid areas with high levels of noise and electrical noise.
Select a location that is large enough to accommodate the LaserPro E200, an exhaust system,
a computer and a work or storage table.
Select a location in which the ambient temperature remains between 15°C and 3C (60°F to
85°F).
Select a location in which the relative humidity remains between 30% - 40%.
Select a location in which there is a short, direct path to the fume exhaust system.
Set the LaserPro E200 on a floor surface that is completely even.
Make sure your smoke or fire detection system in the immediate area is functioning.
Setup the machine to be at least 60 cm (2 feet) away from the wall.
1.7 Noise Test
Test Conditions: measured at a distance of 1 meter from the surface of the machinery and a height of 1.6
meters from the floor or access platform.
E200 40W Sound Test Result: 68.4 dB