55 Fixed
Medical
24-hour audible fixed medical
emergency buttons. Sirens shut off
when reported.
1, 2, 3, 4, 5 Medical/Medical Instant
√ √ √ √
56 Portable
Medical
24-hour audible portable medical
emergency buttons.
1, 2, 3, 4, 5 Medical/Medical Instant
√ √ √
57 Portable
Medical
24-hour audible portable medical
emergency buttons. Sirens shut off
when reported.
1, 2, 3, 4, 5 Medical/Medical Instant
√ √ √
58 Suspicion If not canceled within 1-15 min.,
alarm may optionally be
generated. A second trip within 1-
15 min. will cause an alarm.
1, 2, 3, 4, 5 Suspicion/Silent Instant
√ √ √ √
59 Fire
Keyswitch
Keyswitch used for enabling fire
type touchpad.
1, 2, 3, 4, 5 Silent Instant
√ √
60
(A)
Police 24-hour audible police emergency
buttons.
3, 5 Police/Police Instant
√ √ √ √ √
60
(B)
Fire 24-hour audible fire emergency
buttons
1, 2, 4, Fire/Fire Instant
√ √ √ √ √
61 Local
Indicator/
Delay
Perimeter
Local beeps only in Level -1. 2, 3, 4, 5 Police/Police Standard
√ √ √ √ √ √
62 Fire Panic Fire Panic 1, 2, 3, 4, 5 Fire/Fire Instant
√ √ √ √
63 Equipment
Tamper
24-hour audible security system
panel tamper alarm.
1, 2, 3, 4, 5 Equipment
Tamper/Police
Instant
√ √ √ √
64 Silent
Burglary
24-hour silent security system
panel burglary alarm.
1, 2, 3, 4, 5 Silent Burglary Instant
√ √ √ √
65 Siren
Tamper
24-hour audible siren tamper
alarm.
1, 2, 3, 4, 5 Siren Tamper/
Police
Instant
√ √ √ √
66 Silent
Burglary
24-hour silent burglary alarm. 1, 2, 3, 4, 5 Silent Burglary Instant
√ √ √ √
67 Explosive
Gas
Explosive Gas Detectors 1, 2, 3, 4, 5 Explosive Gas/
Fire
Instant
√ √ √ √
68 Carbon
Monoxide
Carbon Monoxide gas detectors.
Note: For residential use only.
1, 2, 3, 4, 5 Carbon
Monoxide/
Medical
Instant
√ √ √ √
69 Touchpad
disable
keyswitch
Keyswitch for disabling touchpad. 1, 2, 3, 4, 5 None/None Instant
√ √
70 Warning Trip plays programmable
evacuation message.
1, 2, 3, 4, 5 None/None Instant
√ √ √
71 On/Off
Keyswitch
Trip causes arm. Restoral causes a
disarm.
1, 2, 3, 4, 5 None/None Instant
√ √ √
72 Momentary
Keyswitch
First trip arms, second trip
disarms.
1, 2, 3, 4, 5 None/None Instant
√ √
73 Fixed
Holdup
24-hour silent fixed holdup
emergency button alarm.
1, 2, 3, 4, 5 Holdup/None Instant
√ √
74 Portable
Holdup
24-hour silent portable holdup
emergency button alarm.
1, 2, 3, 4, 5 Holdup/None Instant
√
Table B.1 Zone Type Characteristics (Continued)
No. Name Application
Active Level
Alarm/Siren
Delay
Supervisory
Restoral
CS Alarm Report
CS Cancel Report
Bypassable
Chime
Resets Activity Timer