ID-## Drive Information ID-42 Voltage DR-12 Motor Voltage DR-6# Inputs & Outputs DR-95 Ext. Status Word 2
ID-0# Operating Data ID-43 Software Version DR-13 Frequency DR-60 Digital Input DR-96 Maintenance Word
ID-00 Operating Hours ID-44 GE Model Number DR-14 Motor Current
DR-61 Terminal 53 Switch
Setting LG-## Logs & I/O Opt Status
ID-01 Running Hours ID-45 Actual Typecode String DR-15 Frequency [%] DR-62 Analog Input 53 LG-0# Maintenance Log
ID-02 kWh Counter ID-46 GE Product No. DR-16 Torque [Nm]
DR-63 Terminal 54 Switch
Setting LG-00 Maintenance Log: Item
ID-03 Power Up's ID-47 GE Power Card Model No DR-17 Speed [RPM] DR-64 Analog Input 54 LG-01 Maintenance Log: Action
ID-04 Over Temp's ID-48 Keypad ID Number DR-18 Motor Thermal DR-65 Analog Output 42 [mA] LG-02 Maintenance Log: Time
ID-05 Over Volt's ID-49 SW ID Control Card DR-22 Torque [%] DR-66 Digital Output [bin]
LG-03 Maintenance Log: Date and
Time
ID-06 Reset kWh Counter ID-50 SW ID Power Card DR-3# Drive Status DR-67 Freq. Input #29 [Hz] LG-1# Fire Mode Log
ID-07 Reset Running Hours Counter ID-51 Drive Serial Number DR-30 DC Link Voltage DR-68 Freq. Input #33 [Hz] LG-10 Fire Mode Log: Event
ID-08 Number of Starts ID-53 Power Card Serial Number DR-32 Brake Energy /s DR-69 Pulse Output #27 [Hz] LG-11 Fire Mode Log: Time
ID-1# Data Trending Set ID-6# Option Ident DR-33 Brake Energy /2 min DR-70 Pulse Output #29 [Hz]
LG-12 Fire Mode Log: Date and
Time
ID-10 Trending Source ID-60 Option Mounted DR-34 Heatsink Temp. DR-71 Relay Output [bin] LG-3# I/O Option Status
ID-11 Trending Interval ID-61 Option SW Version DR-35 Drive Thermal DR-72 Counter A LG-30 Analog Input X42/1
ID-12 Trigger Event ID-62 Option Ordering No DR-36 Drive Nominal Current DR-73 Counter B LG-31 Analog Input X42/3
ID-13 Trending Mode ID-63 Option Serial No DR-37 Drive Max. Current DR-75 Analog In X30/11 LG-32 Analog Input X42/5
ID-14 Samples Before Trigger ID-9# Parameter Info DR-38 Logic Controller State DR-76 Analog In X30/12 LG-33 Analog Out X42/7 [V]
ID-2# Historic Log ID-92 Defined Parameters DR-39 Control Card Temp. DR-77 Analog Out X30/8 [mA] LG-34 Analog Out X42/9 [V]
ID-20 Historic Log: Event ID-93 Modified Parameters DR-40 Trending Buffer Full
DR-8# Serial communication
bus & Drive Port LG-35 Analog Out X42/11 [V]
ID-21 Historic Log: Value DR-## Data Readouts DR-43 Timed Actions Status DR-80 Fieldbus CTW 1 AP-## HVAC Appl. Param.
ID-22 Historic Log: Time DR-0# General Status DR-49 Current Fault Source DR-82 Fieldbus REF 1 AP-0# Miscellaneous
ID-23 Historic Log: Date and Time DR-00 Control Word DR-5# Ref. & Feedb. DR-84 Comm. Option STW AP-00 External Interlock Delay
ID-3# Alarm Log DR-01 Reference [Unit] DR-50 External Reference DR-85 Drive Port CTW 1 AP-2# No-Flow Detection
ID-30 Alarm Log: Error Code DR-02 Reference [%] DR-52 Feedback [Unit] DR-86 Drive Port REF 1 AP-20 Low Power Auto Set-up
ID-31 Alarm Log: Value DR-03 Status Word DR-53 Digi Pot Reference DR-9# Diagnosis Readouts AP-21 Low Power Detection
ID-32 Alarm Log: Time DR-05 Main Actual Value [%] DR-54 Feedback 1 [Unit] DR-90 Alarm Word AP-22 Low Speed Detection
ID-33 Alarm Log: Date and Time DR-09 Custom Readout DR-55 Feedback 2 [Unit] DR-91 Alarm Word 2 AP-23 No-Flow Function
ID-4# Drive Identification DR-1# Motor Status DR-56 Feedback 3 [Unit] DR-92 Warning Word AP-24 No-Flow Delay
ID-40 Drive Type DR-10 Power [kW] DR-58 PID Output [%] DR-93 Warning Word 2 AP-26 Dry Pump Function
ID-41 Power Section DR-11 Power [hp] DR-94 Ext. Status Word AP-27 Dry Pump Delay
Table 5.7
About Programming AF-600 FP Design and Installation Guide
5-10 DET-768A