AP-3# No-Flow Power Tuning AP-71 Compressor Start Max Speed [Hz] FB-09 Fire Mode Alarm Handling
T-14 Maintenance Date and
Time CL-03 Feedback 2 Source
AP-30 No-Flow Power
AP-72 Compressor Start Max Time to
Trip FB-1# Drive Bypass T-15 Reset Maintenance Word CL-04 Feedback 2 Conversion
AP-31 Power Correction Factor AP-73 Starting Acceleration Time FB-10 Drive Bypass Function T-16 Maintenance Text CL-05 Feedback 2 Source Unit
AP-32 Low Speed [RPM] AP-75 Short Cycle Protection FB-11 Drive Bypass Delay Time T-5# Energy Log CL-06 Feedback 3 Source
AP-33 Low Speed [Hz] AP-76 Interval between Starts FB-20 Locked Rotor Function T-50 Energy Log Resolution CL-07 Feedback 3 Conversion
AP-34 Low Speed Power [kW] AP-77 Minimum Run Time FB-21 Locked Rotor Coefficient 1 T-51 Period Start CL-08 Feedback 3 Source Unit
AP-35 Low Speed Power [HP] AP-8# Flow Compensation FB-22 Locked Rotor Coefficient 2 T-53 Energy Log CL-12 Reference/Feedback Unit
AP-36 High Speed [RPM] AP-80 Flow Compensation FB-23 Locked Rotor Coefficient 3 T-54 Reset Energy Log CL-13 Minimum Reference/Feedb.
AP-37 High Speed [Hz]
AP-81 Square-linear Curve Approxi-
mation FB-24 Locked Rotor Coefficient 4 T-6# Trending CL-14 Maximum Reference/Feedb.
AP-38 High Speed Power [kW] AP-82 Work Point Calculation FB-30 Missing Motor Function T-60 Trend Variable CL-20 Feedback Function
AP-39 High Speed Power [HP] AP-83 Speed at No-Flow [RPM] FB-31 Missing Motor Coefficient 1 T-61 Continuous Bin Data CL-21 Setpoint 1
AP-4# Sleep Mode AP-84 Speed at No-Flow [Hz] FB-32 Missing Motor Coefficient 2 T-62 Timed Bin Data CL-22 Setpoint 2
AP-40 Minimum Run Time AP-85 Speed at Design Point [RPM] FB-33 Missing Motor Coefficient 3 T-63 Timed Period Start CL-23 Setpoint 3
AP-41 Minimum Sleep Time AP-86 Speed at Design Point [Hz] FB-34 Missing Motor Coefficient 4 T-64 Timed Period Stop CL-3# Feedback Adv. Conv
AP-42 Wake-up Speed [RPM] AP-87 Pressure at No-Flow Speed T-## Timed Functions T-65 Minimum Bin Value CL-30 Refrigerant
AP-43 Wake-up Speed [Hz] AP-88 Pressure at Rated Speed T-0# Timed Actions
T-66 Reset Continuous Bin
Data CL-31 User Defined Refrigerant A1
AP-44 Wake-up Ref./FB Difference AP-89 Flow at Design Point T-00 ON Time T-67 Reset Timed Bin Data CL-32 User Defined Refrigerant A2
AP-45 Setpoint Boost AP-90 Flow at Rated Speed T-01 ON Action T-8# Payback Counter CL-33 User Defined Refrigerant A3
AP-46 Maximum Boost Time FB-## Fire/Bypass Operation T-02 OFF Time T-80 Power Reference Factor CL-34 Duct 1 Area [m2]
AP-5# End of Curve FB-0# Fire Mode T-03 OFF Action T-81 Energy Cost CL-35 Duct 1 Area [in2]
AP-50 End of Curve Function FB-00 Fire Mode Function T-04 Occurrence T-82 Investment CL-36 Duct 2 Area [m2]
AP-51 End of Curve Delay FB-01 Fire Mode Configuration T-08 Timed Actions Mode T-83 Energy Savings CL-37 Duct 2 Area [in2]
AP-6# Broken Belt Detection FB-02 Fire Mode Unit T-09 Timed Actions Reactivation T-84 Cost Savings CL-38 Air Density Factor [%]
AP-60 Broken Belt Function FB-03 Fire Mode Min Reference T-1# Maintenance CL-## PID Closed-loop CL-7# PID Autotuning
AP-61 Broken Belt Torque FB-04 Fire Mode Max Reference T-10 Maintenance Item CL-0# Feedback CL-70 Closed Loop Type
AP-62 Broken Belt Delay FB-05 Fire Mode Preset Reference T-11 Maintenance Action CL-00 Feedback 1 Source CL-71 PID Performance
AP-7# Compressor FB-06 Fire Mode Reference Source T-12 Maintenance Time Base CL-01 Feedback 1 Conversion CL-72 PID Output Change
AP-70 Compressor Start Max Speed
[RPM] FB-07 Fire Mode Feedback Source T-13 Maintenance Time Interval CL-02 Feedback 1 Source Unit CL-73 Minimum Feedback Level
Table 5.8
About Programming AF-600 FP Design and Installation Guide
DET-768A 5-11
5
5