A-14 G60 Generator Protection System GE Multilin
A.1 PARAMETER LISTS APPENDIX A
A
9548 PMU 1 V1 Mag Volts Phasor measurement unit 1 positive-sequence voltage magnitude
9550 PMU 1 V1 Angle Degrees Phasor measurement unit 1 positive-sequence voltage angle
9551 PMU 1 V2 Mag Volts Phasor measurement unit 1 negative-sequence voltage magnitude
9553 PMU 1 V2 Angle Degrees Phasor measurement unit 1 negative-sequence voltage angle
9554 PMU 1 V0 Mag Volts Phasor measurement unit 1 zero-sequence voltage magnitude
9556 PMU 1 V0 Angle Degrees Phasor measurement unit 1 zero-sequence voltage angle
9557 PMU 1 Ia Mag Amps Phasor measurement unit 1 phase A current magnitude
9559 PMU 1 Ia Angle Degrees Phasor measurement unit 1 phase A current angle
9560 PMU 1 Ib Mag Amps Phasor measurement unit 1 phase B current magnitude
9562 PMU 1 Ib Angle Degrees Phasor measurement unit 1 phase B current angle
9563 PMU 1 Ic Mag Amps Phasor measurement unit 1 phase C current magnitude
9565 PMU 1 Ic Angle Degrees Phasor measurement unit 1 phase C current angle
9566 PMU 1 Ig Mag Amps Phasor measurement unit 1 ground current magnitude
9568 PMU 1 Ig Angle Degrees Phasor measurement unit 1 ground current angle
9569 PMU 1 I1 Mag Amps Phasor measurement unit 1 positive-sequence current magnitude
9571 PMU 1 I1 Angle Degrees Phasor measurement unit 1 positive-sequence current angle
9572 PMU 1 I2 Mag Amps Phasor measurement unit 1 negative-sequence current magnitude
9574 PMU 1 I2 Angle Degrees Phasor measurement unit 1 negative-sequence current angle
9575 PMU 1 I0 Mag Amps Phasor measurement unit 1 zero-sequence current magnitude
9577 PMU 1 I0 Angle Degrees Phasor measurement unit 1 zero-sequence current angle
9578 PMU 1 Freq Hz Phasor measurement unit 1 frequency
9580 PMU 1 df dt Hz/s Phasor measurement unit 1 rate of change of frequency
9581 PMU 1 Conf Ch --- Phasor measurement unit 1 configuration change counter
10240 SRC 1 Ia THD --- Source 1 phase A current total harmonic distortion
10241 SRC 1 Ia Harm[0] Amps Source 1 phase A current second harmonic
10242 SRC 1 Ia Harm[1] Amps Source 1 phase A current third harmonic
10243 SRC 1 Ia Harm[2] Amps Source 1 phase A current fourth harmonic
10244 SRC 1 Ia Harm[3] Amps Source 1 phase A current fifth harmonic
10245 SRC 1 Ia Harm[4] Amps Source 1 phase A current sixth harmonic
10246 SRC 1 Ia Harm[5] Amps Source 1 phase A current seventh harmonic
10247 SRC 1 Ia Harm[6] Amps Source 1 phase A current eighth harmonic
10248 SRC 1 Ia Harm[7] Amps Source 1 phase A current ninth harmonic
10249 SRC 1 Ia Harm[8] Amps Source 1 phase A current tenth harmonic
10250 SRC 1 Ia Harm[9] Amps Source 1 phase A current eleventh harmonic
10251 SRC 1 Ia Harm[10] Amps Source 1 phase A current twelfth harmonic
10252 SRC 1 Ia Harm[11] Amps Source 1 phase A current thirteenth harmonic
10253 SRC 1 Ia Harm[12] Amps Source 1 phase A current fourteenth harmonic
10254 SRC 1 Ia Harm[13] Amps Source 1 phase A current fifteenth harmonic
10255 SRC 1 Ia Harm[14] Amps Source 1 phase A current sixteenth harmonic
10256 SRC 1 Ia Harm[15] Amps Source 1 phase A current seventeenth harmonic
10257 SRC 1 Ia Harm[16] Amps Source 1 phase A current eighteenth harmonic
10258 SRC 1 Ia Harm[17] Amps Source 1 phase A current nineteenth harmonic
10259 SRC 1 Ia Harm[18] Amps Source 1 phase A current twentieth harmonic
10260 SRC 1 Ia Harm[19] Amps Source 1 phase A current twenty-first harmonic
10261 SRC 1 Ia Harm[20] Amps Source 1 phase A current twenty-second harmonic
10262 SRC 1 Ia Harm[21] Amps Source 1 phase A current twenty-third harmonic
10263 SRC 1 Ia Harm[22] Amps Source 1 phase A current twenty-fourth harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 14 of 23)
ADDRESS FLEXANALOG NAME UNITS DESCRIPTION