A-18 G60 Generator Protection System GE Multilin
A.1 PARAMETER LISTS APPENDIX A
A
10453 SRC 3 Ia Harm[14] Amps Source 3 phase A current sixteenth harmonic
10454 SRC 3 Ia Harm[15] Amps Source 3 phase A current seventeenth harmonic
10455 SRC 3 Ia Harm[16] Amps Source 3 phase A current eighteenth harmonic
10456 SRC 3 Ia Harm[17] Amps Source 3 phase A current nineteenth harmonic
10457 SRC 3 Ia Harm[18] Amps Source 3 phase A current twentieth harmonic
10458 SRC 3 Ia Harm[19] Amps Source 3 phase A current twenty-first harmonic
10459 SRC 3 Ia Harm[20] Amps Source 3 phase A current twenty-second harmonic
10460 SRC 3 Ia Harm[21] Amps Source 3 phase A current twenty-third harmonic
10461 SRC 3 Ia Harm[22] Amps Source 3 phase A current twenty-fourth harmonic
10462 SRC 3 Ia Harm[23] Amps Source 3 phase A current twenty-fifth harmonic
10471 SRC 3 Ib THD --- Source 3 phase B current total harmonic distortion
10472 SRC 3 Ib Harm[0] Amps Source 3 phase B current second harmonic
10473 SRC 3 Ib Harm[1] Amps Source 3 phase B current third harmonic
10474 SRC 3 Ib Harm[2] Amps Source 3 phase B current fourth harmonic
10475 SRC 3 Ib Harm[3] Amps Source 3 phase B current fifth harmonic
10476 SRC 3 Ib Harm[4] Amps Source 3 phase B current sixth harmonic
10477 SRC 3 Ib Harm[5] Amps Source 3 phase B current seventh harmonic
10478 SRC 3 Ib Harm[6] Amps Source 3 phase B current eighth harmonic
10479 SRC 3 Ib Harm[7] Amps Source 3 phase B current ninth harmonic
10480 SRC 3 Ib Harm[8] Amps Source 3 phase B current tenth harmonic
10481 SRC 3 Ib Harm[9] Amps Source 3 phase B current eleventh harmonic
10482 SRC 3 Ib Harm[10] Amps Source 3 phase B current twelfth harmonic
10483 SRC 3 Ib Harm[11] Amps Source 3 phase B current thirteenth harmonic
10484 SRC 3 Ib Harm[12] Amps Source 3 phase B current fourteenth harmonic
10485 SRC 3 Ib Harm[13] Amps Source 3 phase B current fifteenth harmonic
10486 SRC 3 Ib Harm[14] Amps Source 3 phase B current sixteenth harmonic
10487 SRC 3 Ib Harm[15] Amps Source 3 phase B current seventeenth harmonic
10488 SRC 3 Ib Harm[16] Amps Source 3 phase B current eighteenth harmonic
10489 SRC 3 Ib Harm[17] Amps Source 3 phase B current nineteenth harmonic
10490 SRC 3 Ib Harm[18] Amps Source 3 phase B current twentieth harmonic
10491 SRC 3 Ib Harm[19] Amps Source 3 phase B current twenty-first harmonic
10492 SRC 3 Ib Harm[20] Amps Source 3 phase B current twenty-second harmonic
10493 SRC 3 Ib Harm[21] Amps Source 3 phase B current twenty-third harmonic
10494 SRC 3 Ib Harm[22] Amps Source 3 phase B current twenty-fourth harmonic
10495 SRC 3 Ib Harm[23] Amps Source 3 phase B current twenty-fifth harmonic
10504 SRC 3 Ic THD --- Source 3 phase C current total harmonic distortion
10505 SRC 3 Ic Harm[0] Amps Source 3 phase C current second harmonic
10506 SRC 3 Ic Harm[1] Amps Source 3 phase C current third harmonic
10507 SRC 3 Ic Harm[2] Amps Source 3 phase C current fourth harmonic
10508 SRC 3 Ic Harm[3] Amps Source 3 phase C current fifth harmonic
10509 SRC 3 Ic Harm[4] Amps Source 3 phase C current sixth harmonic
10510 SRC 3 Ic Harm[5] Amps Source 3 phase C current seventh harmonic
10511 SRC 3 Ic Harm[6] Amps Source 3 phase C current eighth harmonic
10512 SRC 3 Ic Harm[7] Amps Source 3 phase C current ninth harmonic
10513 SRC 3 Ic Harm[8] Amps Source 3 phase C current tenth harmonic
10514 SRC 3 Ic Harm[9] Amps Source 3 phase C current eleventh harmonic
10515 SRC 3 Ic Harm[10] Amps Source 3 phase C current twelfth harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 18 of 23)
ADDRESS FLEXANALOG NAME UNITS DESCRIPTION