Segment 1
Partition 1 “Tamper Code”
Segment 2
Partition 2 “Tamper Code”
Segment 3
Partition 3 “Tamper Code”
Segment 4
Partition 4 “Tamper Code”
LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4 segments,
numerical data)
Location 59 contains the event code for a zone “Trouble” with a 4+2 and 3+1 format. For the 4+2
format, the digit programmed in this location will be sent as the tens digit of the trouble event code.
The zone ID will always be reported as the ones digit of the zone number (e.g. zone 12 = 2, zone 44
= 4).
This location contains 4 segments. Any segment left as “0” will follow segment 1 selection.
Segment 1
Partition 1 “Trouble Code”
Segment 2
Partition 2 “Trouble Code”
Segment 3
Partition 3 “Trouble Code”
Segment 4
Partition 4 “Trouble Code”
LOCATION 60 - SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
(4 segments, numerical data)
Location 60 contains the event code for a zone “Sensor Low Battery” for a 4+2 and 3+1 format. For a
4+2 format, the digit programmed in this location will be sent as the tens digit of the sensor low
battery event code. The zone ID will always be reported as the ones digit of the zone number (e.g.
zone 12 = 2, zone 44 = 4).
This location contains 4 segments. Any segment left as “0” will follow the Segment 1 selection.
Segment 1
Partition 1 “Sensor Low battery Code”
Segment 2
Partition 2 “Sensor Low battery Code”
Segment 3
Partition 3 “Sensor Low battery Code”
Segment 4
Partition 4 “Sensor Low battery Code”
LOCATION 61 - SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4
segments, numerical data)
Location 61 contains the event code for a zone “Sensor-missing” for a 4+2 and 3+1 format. For a 4+2
format, the digit programmed in this location will be sent as the tens digit of the sensor missing event
code. The zone ID will always be reported as the ones digit of the zone number (e.g. zone 12 = 2,
zone 44 = 4).
This location contains 4 segments. Any segment left as “0” will follow the Segment 1 selection.
Segment 1
Partition 1 “Sensor Missing Code”
Segment 2
Partition 2 “Sensor Missing Code”
Segment 3
Partition 3 “Sensor Missing Code”
Segment 4
Partition 4 “Sensor Missing Code”