7. Set the value of Inputs>Swinger Count to 5. For more information see Setting swinger
count below.
Setting swinger count
The swinger shutdown function allows the selected zone to be automatically bypassed after a
specified number of alarms. To configure swinger count, you must enable the advanced menu. The
following example sets swinger count to 5. This means that any zone for which swinger shutdown is
enabled can be activated five times within one arm period before it is automatically bypassed.
Bypassing a swinger zone also resets the counter for that zone to zero.
1. Ensure the advanced menu is enabled.
2. Navigate with the ½¾ keys to Control Panel>Inputs>Swinger Count and press OK.
3. Enter 5 and press OK.
4. The keypad beeps once to confirm the change and returns to Swinger Count.
Programming outputs
Figure 14. Outputs menu
1 (< >)Any Siren
Event
Alarms
Arm/Disarm
Communications
Keypads
Sirens
Tamper/Fault
Tests
Miscellaneous
2.2.1.1.1
2.2.1.1.1.1
2.2.1.1.1.8
2.2.1.1.1.7
2.2.1.1.1.6
2.2.1.1.1.5
2.2.1.1.1.4
2.2.1.1.1.3
2.2.1.1.1.2
Prog Outputs
2.2.1 2.2.1.1
Outputs 2 - 4
Same as above
Sounds On
Short Blast On
Output Signal Type
Sound On
Time Unit
Time
Partitions
Attributes
Phone Line Cut
Tampers
Expander Trouble
Cross Zone Verification
Arming
Exit Expir
Closing Kissoff
Keyswitch Arming
Delay ed
Phone Line Cut
Mains Failure
Low Battery
Tampers
Expander
Cross Zone Verification
Trouble
Emergency Keys
Latched
Code Stops Timer
Only if Closed
Only if Open
Inverted
When Armed
When Disarmed
When Armed
When Disarmed
2.2.1.1.2
2.2.1.1.5
2.2.1.1.4
2.2.1.1.3
2.2.2.1.1
2.2.2.2.1
2.2.2.2.4
2.2.2.2.3
2.2.2.2.2
2.2.3.1.1
2.2.3.1.6
2.2.3.1.5
2.2.3.1.4
2.2.3.1.3
2.2.3.1.2
2.2.3.1.1.1
2.2.1.1.5.1
2.2.1.1.5.5
2.2.1.1.5.4
2.2.1.1.5.3
2.2.1.1.5.2
2.2.2.1.1.1
2.2.2.1.3
2.2.2.1.2
2.2.2.1.1.2
2.2.3.1.1.2
Internal Siren
Keypads
2.2.2
2.2.3
2.2.2.1
2.2.2.2
2.2.2.3
2.2.3.1
2.2.2.1.4
2.2.3.1.7

Table of Contents

Other manuals for GE NX-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-10 and is the answer not in the manual?

GE NX-10 Specifications

General IconGeneral
BrandGE
ModelNX-10
CategorySecurity System
LanguageEnglish

Related product manuals