Configuring partitions
Figure 18. Partitions menu
A partition is a group of zones which operate as a unit and can be armed and disarmed independently
of other partitions in the system. A partition is also known as an area. The control panel can be
divided into separate partitions with distinct zones, keypad and user codes for each partition. Arming
and bypass options can be set for each partition. To program partition settings, select Installer
Menu>Control Panel>Partition Settings.
Setting timers
You can specify the time in which a user must disarm or arm a system before a full alarm occurs. The
following example sets time within which the user must disarm the system (10 seconds). It also sets
the time within which the user must leave the protected zone after arming the system (12 seconds).
1. Navigate with the ½¾ keys to Control Panel>Partition
Settings>Partition 1>Timers>Entry 1 and press OK.
2. Enter 10 and press OK.
3. The keypad beeps once to confirm the change and returns to Entry 1.
4. Scroll to Exit 1 and press OK.
5. Enter 12 and press OK.
6. The keypad beeps once to confirm the change and returns to Exit 1.
Configuring a partition
You can set partition features including arming and bypassing options. You can also enable life
safety keys for the partition keypads. The following example allows the system to be armed silently
Entry 1
Exit 1
Entry 2
Exit 2
Time
Time
Time
Time
Arming
Quick Arm
Autom. Instant
Final Set Door
Instant Night
Arm with Tamper Mem/FTC
Arm with Low Battery
Keyswitch Arm STAY
Late to Close/Early to Open
Auto Arm in Stay Mode
Re-exit
Silent Auto Arm
Instant Stay Toggle
Miscellaneous
Silent PA
Audible PA
Fire/Aux 1
Medical/Aux 2
Tamper
LED Extinguish
Keypress
Bypass
Auto Bypass
Code Required
Sounder Alert
Bypass Toggle
No Forced Bypass
Mains/Batt Sounder Alert
Tamper if Zone Lost
Timers
Feature Select
2.5.1.1
2.5.1.2
2.5.1.1.1
2.5.1.1.2
2.5.1.1.3
2.5.1.1.4
2.5.1.2.1
2.5.1.2.2
2.5.1.2.3
2.5.1.2.4
2.5.1.2.1.1
2.5.1.2.1.2
2.5.1.2.1.3
2.5.1.2.1.4
2.5.1.2.1.5
2.5.1.2.2.1
2.5.1.2.2.2
2.5.1.2.2.3
2.5.1.2.2.4
2.5.1.2.2.5
2.5.1.2.2.6
2.5.1.2.3.1
2.5.1.2.3.2
2.5.1.2.3.3
2.5.1.2.3.4
2.5.1.2.4.1
2.5.1.2.4.2
Keypads
(1) Partition 1
2.5.1
Partitions 2 4 -
Same as above
2.5.1.2.1.6
2.5.1.2.1.7
2.5.1.2.1.8
2.5.1.2.1.9
2.5.1.2.1.10
2.5.1.2.1.11
2.5.1.2.1.12
2.5.1.2.3.5

Table of Contents

Other manuals for GE NX-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-10 and is the answer not in the manual?

GE NX-10 Specifications

General IconGeneral
BrandGE
ModelNX-10
CategorySecurity System
LanguageEnglish

Related product manuals