To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
7. Navigate with the ½¾ keys to Schedule Times>Closing/Autoarm>Hour and press OK.
8. Enter 18 and press OK.
9. The keypad beeps once to confirm the change and returns to Hour.
10. Scroll to Minute and press OK.
11. Enter 0 and press OK.
12. The keypad beeps once to confirm the change and returns to Minute.
Glossary
Location Term Definition
2 Control Panel This groups all options relating to the central processing
unit of the alarm system. The control panel monitors the
detection devices and activates any number of signalling
devices.
2.1 Inputs A menu entry that groups options relating to all zones.
2.1.1 Zones A menu entry that groups zone options.
2.1.1.1.1 Zone Type A menu option that specifies the zone type of a particular
zone.
2.1.1.1.2 Zone Name A menu option that allows the installer to define names for
each installed zone. For example, Zone 1 can be named
Living Room PIR.
2.1.1.1.3 Partitions A menu entry that lists the partitions assigned to the
selected zone. The selected zone can trigger an event on
these partitions.
A zone may reside in any combination of partitions. A zone
that resides in more than one partition becomes a
common zone and is reported to its lowest partition
number. A common zone is armed only when all the
partitions that it belongs to are armed. It is disarmed the
moment one of the partitions it belongs to is disarmed.
2.1.1.1.4 Copy Zone A menu option that copies the settings for an individual
zone to a contiguous set of other zones.
2.1.2 Swinger Count A zone characteristic that includes the selected zone in the
swinger counter for an partition. Each partition has a
swinger counter, and every zone trip in that partition
increments the swinger count for that partition. When the
count reaches the programmed number of trips, the panel
bypasses the last tripped zone and clears the counter.
An Inputs menu entry that contains the swinger count.
2.1.3 Zone Types A menu entry that groups zone type characteristics and
allows the installer to select a pre-defined zone type. There
are 30 pre-defined zone types. The characteristics of each
zone can be changed. For example, if a keypad beeps, if
the zone is a delay 1 or delay 2 zone, a 24-hour zone and
so on.
2.1.3.1.1 Input Type A menu entry that groups options that determine the basic
features of the selected zone type.
2.1.3.1.1.1 Fire A zone type that reports a fire alarm when activated.