the Arm Away function works as a single-button shortcut only in the single-partition mode if the
Installer Menu>Control Panel>Partition Settings>Partition 1>Feature Select>Arming>Quick Arm
menu option was set. Some functions are assigned to particular keys by default, and can be made
permanent (fixed) at the factory.
Note: When arming the system with a function key, both logs and reports show User 98 as the user who armed the
system.
There are the following default key assignments:
Table 14. Default function key assignments
Key Default function
F1 Panic Keypad
F2 Fire Alarm
F3 Arm Away (factory fixed key)
F4 Arm Stay (factory fixed key)
F5 Disarm (works in Master Mode only) (factory fixed key)
F6 Select zones to bypass (factory fixed key)
F7 Arm in Night Mode
F8 Medical
You can program any function key, unless it is fixed at the factory. The following example
configures the F1 key so it performs the manual fire alarm function.
1. Navigate with the ½¾ keys to Installer Menu>This Keypad>Function Keys and press
OK.
2. Scroll to F1 Function>Fire Alarm and press OK.
3. The keypad beeps once to confirm the change and returns to F1 Function.
4. Navigate with the ½¾ keys to Control Panel>Partition Settings>Partition 1>Feature
Select>Keypads>Fire/Aux 1 and press OK.
5. Select Enabled and press OK.
6. The keypad beeps once to confirm the change and returns to Fire/Aux 1.
Table 15. Available function key actions
Function Action description
Disabled Disables the function key.
Arm Away Mode Arms the system in Away mode. Arming with the function key will report as User 98.
Note: This shortcut works only if the Quick Arm menu option was set. It works differently in
the master mode and in the single-partition mode. For more information, see the Master
Keypad, and the Quick Arm menu option descriptions in the glossary.
Arm Stay Mode Arms the system in Stay mode. Arming with the function key will report as User 98.
Note: This shortcut works only if the Quick Arm menu option was set. For the Stay mode to
work correctly, interior zones must be set. It works differently in the master mode and in the
single-partition mode. For more information on this button behaviour, see the Master
Keypad, and the Quick Arm menu option description in the glossary.
Bypass Zones Selects a zone to bypass. It is a shortcut for the User Menu>Bypass Zones menu option.
The Enter Zone No. prompt displays. Type the zone number and press OK. Repeat this action
for subsequent zones you want to bypass. To remove a zone from the bypassed zone set
enter its number a
g
ain. To
p
artarm the s
y
stem with the selected zones b
yp
assed, enter the

Table of Contents

Other manuals for GE NX-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-10 and is the answer not in the manual?

GE NX-10 Specifications

General IconGeneral
BrandGE
ModelNX-10
CategorySecurity System
LanguageEnglish

Related product manuals