EasyManuals Logo

GE NX-10 Installer Manual

GE NX-10
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
NX-10 Installers manual
155
Location Term Definition
3.2 Partition Number A menu entry menu option that specifies the partition that
the selected keypad can access if it is a single-partition
keypad. Together with the keypad number, it determines
the keypad bus module number for both single-partition
and master keypads.
3.3 Keypad Features A menu entry that groups keypad options.
3.3.1 Case Tamper
A menu option that sends a tamper report to the central
station and activates a siren and/or the keypad when
interference with keypad housing occurs.
A tamper occurs when the casing of a piece of hardware
(for example, the control panel, sound box or keypad) is
interfered with. The panel has an input for a normally
closed tamper switch. When opened, a box/case tamper is
reported as an event.
3.3.2 Silent Keypad A menu option that silences the keypad’s entry/exit
sounder and chime only.
3.3.3 Ding Dong Chime
A menu option that sets the sound a chime makes. It is
either a ding dong or a beep.
3.3.4 5 sec silence
A menu option that silences the pulsing keypad sounder
for five seconds when a key is pressed.
3.3.5 Armed Zone Info A menu option that enables the mode that displays zone
status on the keypad when the system is armed. When this
mode is disabled, zone status information is not displayed
when armed.
3.3.6 Beep on Panics
A menu option that sounds a keypad beep when the panic
function key (personal attack alarm, medical alarm or fire
alarm) is held down. When this option is disabled, all three
panic function keys are mute (no keystroke sound is
emitted).
3.3.7 Master Keypad
A menu option that sets the default mode of the selected
keypad to master mode. This is a mode of operation on a
keypad that allows a user or installer access multiple
partitions within the system and to perform functions in
these partitions. In order to arm (in Stay, Night or Away
mode) or disarm a partition the user must enter the user
code, select the partition, and then press the appropriate
function button.
A master keypad can be temporarily switched to operate
in single-partition mode and a single-partition keypad can
be temporarily switched to operate in master mode.
3.3.8 Service Message A menu option that enables or disables the service
messages on the keypad.
A message displayed on the LCD keypad informing the
user or installer of a system fault. The service message
disappears from the keypad when the installer enters and
leaves programming mode. The message is used as an
Engineer Reset.
3.3.9 Custom Message A menu option that shows or hides the custom message
on the LCD keypad.
3.3.10 Custom Message Lock A menu option that makes the customized keypad
message on the programmed keypad independent from
other keypads in the system. If disabled, editing the
custom messa
g
e on an
y
ke
yp
ad affects all ke
yp
ads in the

Table of Contents

Other manuals for GE NX-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-10 and is the answer not in the manual?

GE NX-10 Specifications

General IconGeneral
BrandGE
ModelNX-10
CategorySecurity System
LanguageEnglish

Related product manuals