LOC DESCRIPTION DEFAULT PROGRAMMING DATA
Segment 5
Power Trouble (AC Failure / Low
Batt.)
0-0-0-0-0-0-0-0
Segment 6
Siren & Telephone Fault
0-0-0-0-0-0-0-0
Segment 7
Test Reports
0-0-0-0-0-0-0-0
Segment 8
Program, Download, & Log Full
0-0-0-0-0-0-0-0
Segment 9
Tampers (zones and box)
0-0-0-0-0-0-0-0
Segment 10
Short Circuit
0-0-0-0-0-0-0-0
Segment 11
Sensor Lost
0-0-0-0-0-0-0-0
Segment 12
Sensor Low Battery
0-0-0-0-0-0-0-0
Segment 13
Expander Trouble (incl. keypad)
0-0-0-0-0-0-0-0
Segment 14
Failure To Communicate
0-0-0-0-0-0-0-0
Segment 15
Zone Activity Monitoring
0-0-0-0-0-0-0-0
Segment 16
Reserved
0-0-0-0-0-0-0-0
21 DESTINATION SELECTION FOR REPORT
CONTROL 6
0
22 BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 6
0
23 REPORT DELAY FOR REPORT CONTROL 6
0
EVENT SELECTION FOR REPORT CONTROL 6 (BY PARTITION)
Segment 1
Alarms and Restores
0-0-0-0-0-0-0-0
Segment 2
Open/Close
0-0-0-0-0-0-0-0
Segment 3
Bypass
0-0-0-0-0-0-0-0
Segment 4
Zone Trouble
0-0-0-0-0-0-0-0
Segment 5
Power Trouble (AC Failure / Low
Batt.)
0-0-0-0-0-0-0-0
Segment 6
Siren & Telephone Fault
0-0-0-0-0-0-0-0
Segment 7
Test Reports
0-0-0-0-0-0-0-0
Segment 8
Program, Download, & Log Full
0-0-0-0-0-0-0-0
Segment 9
Tampers (zones and box)
0-0-0-0-0-0-0-0
Segment 10
Short Circuit
0-0-0-0-0-0-0-0
Segment 11
Sensor Lost
0-0-0-0-0-0-0-0
Segment 12
Sensor Low Battery
0-0-0-0-0-0-0-0
Segment 13
Expander Trouble (incl. keypad)
0-0-0-0-0-0-0-0
Segment 14
Failure To Communicate
0-0-0-0-0-0-0-0
Segment 15
Zone Activity Monitoring
0-0-0-0-0-0-0-0
24
Segment 16
Reserved
0-0-0-0-0-0-0-0
PRIMARY REPORTING FLAGS FOR REPORT CONTROL 1 TO 6
Segment 1 (Circle Numbers To Program)
1 On = Report Control 1 is Primary Reporting Flag / Off = Report Control 1 is Backup for control panel
2 On = Report Control 2 is Primary Reporting Flag / Off = Report Control 2 is Backup for control panel
3 On = Report Control 3 is Primary Reporting Flag / Off = Report Control 3 is Backup for control panel
4 On = Report Control 4 is Primary Reporting Flag / Off = Report Control 4 is Backup for control panel
5 On = Report Control 5 is Primary Reporting Flag / Off = Report Control 5 is Backup for control panel
6 On = Report Control 6 is Primary Reporting Flag / Off = Report Control 6 is Backup for control panel
7 Reserved
25
8 Reserved
26 - 31 RESERVED
32 PPP (dial-up account) user ID (chars 1 - 16)
33 PPP (dial-up account) user ID (chars 17 - 32)
34 PPP (dial-up account) password
35 – 59 RESERVED
60 Name of GPRS access point - APN (chars 1 - 16)
61 Name of GPRS access point - APN (chars 17 -
32)

Table of Contents

Other manuals for GE NX-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-10 and is the answer not in the manual?

GE NX-10 Specifications

General IconGeneral
BrandGE
ModelNX-10
CategorySecurity System
LanguageEnglish

Related product manuals