NX-10 Installers manual
227
Event message Explanation
Bypass Restore See Bypass event message.
Cancel The report to the central station has been cancelled. This occurs when a user enters a
code after an alarm.
CleanMe A smoke detector is dirty.
CleanMe Restore See CleanMe event message.
Clock Set A user set the date and time.
Close (arm) Closing (arm) by a specific user.
Code Entry The lock of the access reader has been triggered.
The lock can be triggered by an accepted proximity card or by an Egress switch. An
Egress switch is a button that can be pressed by a user to open the lock of the door. It
can also be called Request-to-Exit (RTE). When the Code Entry option is activated, the
reader sends a log message to the control panel, indicating that the lock has been
triggered.
Cross-Trip Tripping the cross zone.
Data Lost The panel has been unable to send alarm messages to the central station. The panel
tries to send these messages a number of times as specified in the FTC (dial attempts
before Fail to Communicate). Any pending reportable events are lost.
Device Tamper
Restore
See Box Tamper event message.
Device Tamper
Restore
See Box Tamper event message.
Disarm from Alarm A user disarmed the panel during an alarm.
Duress A duress code entered by a user. An alarm message is sent to the central station.
Early Open A user disarmed the system before the open time specified in the panel schedules.
End Download The end of an up/download.
End Prog End programming. The installer left programming mode.
End Walktest See Walktest event message.
Enrolled Modules are enrolled on the bus. The module numbers are recorded.
Exit Error An exit door remained open after the exit delay expired.
Expander Fault
Restore
See Expander Trouble event message.
Expander Trouble A problem with an expander module.
Expansion Event A bus device generated an event to report conditions not described by other events.
Fail to Communicate The control panel or module tried to send a message to a central station but failed.
Fault Restore See Trouble event message.
Fire A fire alarm has been tripped.
Fire Restore See Fire event message.