Page #247 background image
NX-10 Installers manual
247
21 KH Heat Alarm Restore
22 FA Manual Fire Alarm
The NX-10 can report Ad emco Contact ID transmissions. Each report in Contact ID consists of an
Event Code and a Zone ID. The zone ID is the zone that generated the alarm. The event code will
come from the chart below, and it will be programmed in the configuration group event code.
Table 39. Reporting zone codes - Contact ID
Programmed Event Code Contact ID Description
0 122 Silent Panic
1 110 Fire Alarm
2 120 Panic alarm
3 130 Burglary Alarm
4 131 Perimeter Alarm
5 132 Interior Alarm
6 133 24 Hour Burglary
7 134 Entry Alarm
8 135 Day/Night Alarm
9 150 Non Burglary 24 Hour
10 121 Duress Alarm
11 100 Medical Alarm
12 123 Audible Panic Alarm
13 137 Tamper Alarm
14 602 Periodic Test
15 151 Gas Detected
16 158 High Temp
17 154 Water Leakage
18 140 General Alarm
19 140 General Alarm
20 159 Low Temp
21 158 Heat Alarm Restore
22 115 Manual Fire Alarm