NX-10 Installers manual
83
Location Term Definition
2.6.1.1.4 Cross Zone Timer A menu option that sets the cross zone time in minutes.
This can be from 0 to 255 minutes, where 0 = no cross
zoning.
2.6.1.2 Power A menu entry that groups the timer options relating to
power events.
2.6.1.2.1 Batt Dynamic Test Duration A menu option that sets the length of time that the control
panel performs the Dynamic Battery test. This can be
between 0 to 30 minutes where 0 is no test.
2.6.1.2.2 Mains Report Delay A menu option that sets the length of time between
detecting a mains failure on the control panel and sending
a report to the central station. The restore event is sent
four minutes after the mains is restored.
2.6.1.2.3 Power Up Delay A menu option that sets the time between mains restore
after a power failure and the system powering up again.
This can be set from 0-60 seconds. 0 means no power up
delay.
2.6.1.3 Sounders A menu entry that groups timers for the internal siren,
external siren and chime duration on the keypad.
2.6.1.3.1 Internal Siren Timeout A menu option that sets the length of time the internal
siren rings before automatically cutting out. This time can
be between 0 and 255 minutes. When set to 0, the siren is
active until a valid code is entered on the keypad.
2.6.1.3.2 Chime Time A menu option that sets the length of time that the chime
operates. This time can be set in 50 ms (1/20th second)
increments from 0-12 seconds. 0 = follows zone.
2.6.1.4 Communications A menu option that groups timers for communication
events.
2.6.1.4.1 Dialer Abort Delay A menu option that creates a delay, programmed in
seconds, in reporting an alarm to the central station.
2.6.1.4.2 Listen-in Time A menu option that sets the length of time the central
station can listen for sounds of intrusion by means of
microphones at the alarm site.
2.6.1.4.3 Phone Line Cut Delay A menu option that sets the length of time before a phone
line cut is signalled after a phone line cut is detected.
A phone line fault is displayed in Service Check>Reset when
Phone Line Cut Delay = 0.
2.6.1.5.1 Programming Mode Timeout A menu option that sets the length of time the control
panel can be in programming mode. This time can be
between 1 and 255 minutes. When set to 0, the
programming mode times out after 15 minutes.
2.6.1.5.2 Auto Arm Warning Time A menu option that sets the length of the warning signal
emited during auto arming. This time can be between 1
and 255 minutes, with 1 minute being a default value.
2.6.1.5.3 Auto Arm Retry Timer A menu option that sets the auto arm cycle timer. This time
can be between 1 and 255 minutes, with 45 minutes as a
default value.

Table of Contents

Other manuals for GE NX-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-10 and is the answer not in the manual?

GE NX-10 Specifications

General IconGeneral
BrandGE
ModelNX-10
CategorySecurity System
LanguageEnglish

Related product manuals