Chapter 2. Installation
24 TransPort
®
PT900 User’s Manual
2.5.6b Odd-Traverse Installations (cont.)
4. Rotate the yoke until it is located in a horizontal position on the opposite
side of the pipe from the previously installed clamping fixture, as shown
in Figure 28 below.
Figure 28: Yoke Rotated into Horizontal Position
5. Ensure that the top surfaces of the yoke bracket and the clamping fixture
brackets lie precisely in the same horizontal plane (see Figure 28 above).
Place the fixed clamp in the clamping fixture at zero on the scale.
Note: If the required axial spacing is 305-375 mm/12 in.-14.8 in., place the fixed
clamp at 100/4 in. on the scale instead of zero.
[Spacing >305 mm/12 in.]
[Spacing <305 mm/12 in.]
Bracket Surfaces
Bracket Surfaces