11.8.3.2 4-Digit Year
Parameter Block Format:
Example:
High Byte Low Byte
Read Date and Time in Packed ASCII
Format (Mon, Oct. 5, 1998 at 11:13:00pm)
1 = change or 0 = read
address
0 (read)
83h (ASCII 4 digit)
address + 1
83h (ASCII 4 digit)
year
(hundreds)
year
(thousands)
address + 2
39 (9) 31 (1)
year (ones) year (tens)
address + 3
38 (8) 39 (9)
month (tens) (space)
address + 4
31 (1) 20 (space)
(space) month (ones)
address + 5
20 (space) 30 (0)
day of month
(ones)
day of month
(tens)
address + 6
35 (5) 30 (leading 0)
hours (tens) (space)
address + 7
31 (1) 20 (space)
: (colon) hours (ones)
address + 8
3A ( : ) 31 (1)
minutes
(ones)
minutes (tens)
address + 9
33 (3) 31 (1)
seconds
(tens)
: (colon)
address + 10
30 (0) 3A ( : )
(space) seconds (ones)
address + 11
20 (space) 30 (0)
day of week
(ones)
day of week
(tens)
address + 12
32 (2: Mon.) 30 (leading 0)
208 GFK-1503E VersaMax PLC User Manual