EasyManuals Logo

GEA VARIVENT X R Series User Manual

GEA VARIVENT X R Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Spring-to-open valve (NO)
INFO Mounting step: mount the clamp connection between the housing and
lantern
T
ools
Jaw wrench a/f 10
Jaw wr
ench a/f 13
Torque wrench ¼“ 2,5-25 Nm
Socket for wrench ¼" long a/f 10
Socket for wrench ¼" a/f 13
1. Mount the clamp connection (43) be-
tween the housing and lantern.
®
Observe torques, see
9.6.1 Tighten-
ing torques
.
43
78 / 104 - 9.6 Installing the valve
0000000881 - 001 - EN-GB