34
in.xe TechBook
If weather is very hot:
1• Remove spa cover 
(even during the night). 
Start blower if spa is 
equipped with one. 
Wait until spa cools 
down (add cold water 
if necessary).
•   Shut power off and 
power the spa up again 
to reset the system.
3• With a voltmeter, read 
voltage between the 
live and ground heater 
terminals.
4• If you do read 240 V, 
replace spa pack.
5• If you do not read 
240 V, pump may be 
overheating water 
during filter cycle.
  Shorten filter 
cycle duration.
If hot weather is not
a factor:
2• Lower set point 
below current water 
temperature.
  The Heater indicator 
should disappear from 
keypad display.
To shorten filter cycle
duration:
6• Press and hold the 
Light key for 5 seconds. 
Display will show a 
value that represents 
the filter cycle duration 
in hours.
7• Use the Down arrow 
key to lower the 
number of hours.
  0 = no filtration
  12 = continuous filtration
  When the desired 
setting is displayed, 
press Light key again. 
The filter cycle will start 
immediately.
L2 GroundL1N