in.xe TechBook
11
Heater connections
heat.wav heater
in.xe comes with a high performance heat.wav heater.
With no pressure switch, it features in.flo integrated
dry-fire protection.
A watertight panel protects the heater and probe
connectors. Removing the panel gives access to in.flo 
dry-fire protection and hi-limit/regulation probe
connectors, line 1, line 2 and ground power input cables
connection ports.
The heat.wav heater is factory configured 240 V /4 kW
(or 2 kW), but it can be converted to a dedicated
120 V / 1 kW by simply switching a cable connection
port. Option available on North American models only.
heat.wav specification summary:
•  Supports 120 V or 240 V
•  Protected by external breaker (not fused)*
•  Incoloy® or Titanium (optional) heater element
for greater protection against corrosion.
*Note: European models are 230 or 240 V and are fuse protected
GroundN L1
L2 GroundL1
Connections for 120 V
heater (1 kW)
Connections for 230/240 V
heater (4 kW or 2 kW)

Other manuals for Gecko in.xe

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gecko in.xe and is the answer not in the manual?

Gecko in.xe Specifications

General IconGeneral
Blower Output1
Ozone Output1
Light Output1
DimensionsVaries by model
WeightVaries by model
WarrantyVaries by manufacturer
Power Supply240V
Keypad Compatibilityin.k200, in.k300, in.k35, in.k4, in.k450, in.k500, in.k600, in.800 Auxiliary Keypads: in.k100

Related product manuals