46
in.xe TechBook
Spa not heating!
•  Check for an error 
message on keypad 
display. If there is one,
refer to specific sec-
tion indicated by the 
error message.
•  If there is no error 
message, try to raise 
water temperature by 
increasing the set point 
2°F higher than actual 
water temperature. 
Press Up key to
increase set point.
•  If heater indicator lights 
up on the display, take
voltage reading on the 
heater terminals.
Your reading should be:
240 V: Line 1 & Line 2
120 V: Line 1 & Neutral
Heater indicatorset point indicator
•  Verify if Heater 
indicator appears on 
keypad display.
•  The heater indicator 
will be on when heater 
is on. It will flash if
more heat has been 
requested, but heater 
has not started yet.
•  If voltage reading is 
not as it should be, 
verify that heater 
terminals are properly 
connected .
•  If it is as it should be,
replace spa pack.
•  In the case of the
European model 
in.xe.ce only, replace 
accessory fuse.
•  If problem persists, 
replace spa pack.
If a keypad doesn’t seem to work:
•  Verify keypad connections and try spare keypad.
•  Replace keypad if problem is corrected.
•  Replace in.xe if problem is not corrected.
Keypad doesn't seem to work step-by-step
240 V Heater (4 kW or 2 kW)
120 V Heater (1 kW)
L2 GroundL1N
L1N
Keypad connector